• Phone

    86-519-80585809

  • Address

    Floor 21, Jiaoyin Mansion, No. 255, Tongjiang South Road, Tianning Dist., Changzhou, Jiangsu, China (Mainland)

  • E-mail

    k@waimaotong.com

LatestProducts

                            good anti-static pvc vinyl flooring for data center

good anti-static pvc vinyl flooring for data center

good anti-static pvc vinyl flooring for data center,ATFLOR,Construction & Real Estate,Flooring & Accessories
INQUIRY PRECISE INQUIRY
Description

Overview
Quick Details
Place of Origin:
China
Brand Name:
ATFLOR
Model Number:
ATFLOR
Size:
600 x 600mm, Other, 600*600*2mm
Material:
PVC
Usage:
Interior Tiles
Function:
Acid-Resistant, Antibacterial, Firebrick, Heat Insulation, Non-Slip, Wear-Resistant
Surface Treatment:
Full Body Tiles
Tile Type:
Floor Tiles
Type:
Tiles
Color Family:
Blacks, Blues, Browns / Tans, Grays, Greens, Oranges, Purples / Lavenders, Reds / Pinks, Whites, Yellows / Golds
Supply Ability
Supply Ability:
6000 Square Meter/Square Meters per Week
Packaging & Delivery
Packaging Details
pallet
Port
Shanghai
Lead Time :
20 days after down payment

Product Brief : 

1.Permanent and consistent anti-static function with ESD (Electro-Static discharge) Technology

2.Highly stain resistant and outstanding wear resistance with UV Coating surface,make for Lower maintenance cost

3.Excellent in Fire prevention ,moisture proof and anti-corrosion

4.Uniform size and Multiple options in color with Fade Resistant

5 Prominent installation performance and workability

6.Low outgassing emission and dust-free technology Product Type : Conductive & Dissipative

 

 

Antistatic PVC Floor

good anti-static pvc vinyl flooring for data center

 

 

Technical Data

 

 

 

Item

                 Technical Data

THICKNESS EN428

2.0 mm,2.5mm,3.0mm

SIZE EN426

600×600mm

610×610mm

WEIGHT EN430

3.8kg/2.0mm,4.8kg/2.5mm,5.8kg/3.0mm

ELECTRIC PROPERTIES 
DIN51953 ASTM F-150 OR NFPA99

CONDUCTIVE TILE

DISSIPATIVE TILE

10^4~10^6 ohm

10^6~10^9 ohm

DECAY TIME 
SJ/T10694-2006(±1000V±100V≤2s)

EQUAL 0.4S

EQUAL 0.4S

CHARGE VOLTAGE 
SJ/T10694-2006(|V|<100V)

EQUAL 70

EQUAL 70

FIRE RESISTANCE 
DIN4102

B1

B1

COMBUSTION PROPERTIES 
SJ/T11236-2001(<10S,  reachFV-0)

EQUAL 0.35s|FV-0

EQUAL 0.35s|FV-0

AMOUNT OF ANTI-WEAR 
SJ/T11236-2001(≤0.020g/cm21000r)

EQUAL 0.014

EQUAL 0.014

ANTI-WEAR PROPERTIES 
EN660pt2

ITEN-T<2.0mm3

ITEN-T<2.0mm3

WHEEL PRESSURE 
EN425

No influence

No influence

RESIDUAL CONCAVITY 
EN433/DIN51955

0.03mm(2.0 mm) 
0.035 mm(2.5 mm) 
0.04 mm(3.0 mm)

0.03 mm(2.0 mm) 
0.035 mm(2.5 mm) 
0.04mm(3.0 mm)

DIMENSIONAL STABILITY EN434

≤0.10%

≤0.10%

COLOR FASTNESS ISO105BO2

At least 6

At least 6

RESISTANCE TO CHENMICALS DIN423/DIN51958

Offers excellent 
resistance ask for special sheet

Offers excellent resistance ask for special sheet

IMPACT SOUND ABSORPTION VLI,ISO104,ISO717

Approx 2dB

Approx 2dB

STANDARD FOR HEALTH CARE FACILITIES NFPA 99

Confirms to the requirement 
of NFPA99 ineffect at the 
tine of installation

 

 

 

PVC installation guide

1 Materials include:

Dissipative PVC tile

Conductive adhesive

Welding rod

Copper foil

 

2 Main tools include:

Grooving machine, plastic welder, rubber hammer, cutting-off tool, ruler, brush, waxing machine, etc.

 

3 Ground requirements

The basic ground should be clean, dry and flat.

The foundation should be cement or terrazzo ground, but couldnt have the phenomenon of sanding and separation. The strength of surface cement cant be lower than No.75.

The ground should be flat, the unevenness must be less than 2/2000mm or make self-leveling cement ground.

If the foundation is formation, the ground must do waterproofing.

 

4 Note of installation

At installation, the ground residual moisture should not exceed 2.5% (CMDUMB test). The PVC floor, adhesive and job site’s temperature must keep above 18 degrees Celsius in 24 hours before the installation. High quality conductive adhesive and copper foil must be used in the installation.

 

5 PVC installation

Observe the layout of room, delimit datum line.

Lay copper foil. The intersection of the copper foil should be the center of PVC tile. The copper foil should be straight, not curly, not discontinuous. Make sure theres long enough copper foil connected to the grounding terminal.

Brush conductive adhesive to the ground and copper foil. Uniform, overall, let it natural air-dry

Lay PVC tile efficiently when adhesive turn dry and not sticky to hand. The edges of the PVC should align with the datum line. Leave a bit gap about 1~2mm between tiles, but the width should be same. Tap the tiles with rubber hammer. Ensure tiles glued firmly. If the place is less than the length of the tile, precisely measure the size of floor, then cut and places it.

After laying all the PVC tiles, use grooving machine to open welding slot along with the gap. Slot line should be smooth and uniform. Generally, width 3±0.2mm is better.

Welding the slot for elegant appearance

After installation, clean the PVC floor.

 

 good anti-static pvc vinyl flooring for data centergood anti-static pvc vinyl flooring for data centergood anti-static pvc vinyl flooring for data centergood anti-static pvc vinyl flooring for data centergood anti-static pvc vinyl flooring for data centergood anti-static pvc vinyl flooring for data center

 good anti-static pvc vinyl flooring for data centergood anti-static pvc vinyl flooring for data centergood anti-static pvc vinyl flooring for data center

 good anti-static pvc vinyl flooring for data center